Data Flash: Settings; Configuration; 0x4632; SOC Flag Config A; H2. More...
#include <flags.h>
Static Public Member Functions | |
static Flag | TDSETV () |
static Flag | TDCLEARV () |
static Flag | TDSETRSOC () |
static Flag | TDCLEARRSOC () |
static Flag | TCSETV () |
static Flag | TCCLEARV () |
static Flag | TCSETRSOC () |
static Flag | TCCLEARRSOC () |
static Flag | FCSETVCT () |
static Flag | TCSETVCT () |
Data Flash: Settings; Configuration; 0x4632; SOC Flag Config A; H2.
Bit 0: TDSETV—Enables the TD flag set by the cell voltage threshold 0 = Disabled (default) 1 = Enabled Bit 1: TDCLEARV—Enables the TD flag clear by cell voltage threshold 0 = Disabled (default) 1 = Enabled Bit 2: TDSETRSOC—Enables the TD flag set by RSOC threshold 0 = Disabled 1 = Enabled (default) Bit 3: TDCLEARRSOC—Enables the TD flag cleared by the RSOC threshold 0 = Disabled 1 = Enabled (default) Bit 4: TCSETV—Enables the TC flag set by cell voltage threshold 0 = Disabled (default) 1 = Enabled Bit 5: TCCLEARV—Enables the TC flag clear by cell voltage threshold 0 = Disabled (default) 1 = Enabled Bit 6: TCSETRSOC—Enables the TC flag set by the RSOC threshold 0 = Disabled (default) 1 = Enabled Bit 7: TCCLEARRSOC—Enables the TC flag cleared by the RSOC threshold 0 = Disabled 1 = Enabled (default) Bit 8: Reserved Bit 9: Reserved Bit 10: FCSETVCT—Enables the FC flag set by primary charge termination 0 = Disabled 1 = Enabled (default) Bit 11: TCSETVCT—Enables the TC flag set by primary charge termination 0 = Disabled 1 = Enabled (default) Bit 15: 12: Reserved